© GeoAcoustics
2008


 |
GeoPulse Profiler
Specification

Transmitter - Model
5430A
|
Output: |
10
kW with 0.75% duty cycle, continuously adjustable. 2 to 12 kHz,
continuously adjustable. Short circuit proof. Impedance matched. |
| Pulse Cycles: |
1, 2, 4, 8, 16, or 32 cycles of the frequency
selected.
The transmitted output pulse will be phase coherent within 22.5°. |
| Key: |
External: |
2 to 12 V pulse, either + or – leading edge
triggered. Maximum width 50ms to eliminate double triggering. Transformer
isolated. |
| |
Internal: |
Set by internal potentiometer, 1 to 10pps, uncalibrated.
|
| Output to Receiver
or digital sonar processing system: |
Transformer isolated. Frequency response flat
between approximately 1 kHz and 20 kHz. Two modes of operation:
A: Flat gain –0 dB gain
B: Short range TVG -20 dB (10:1) of attenuation during transmit pulse and a
–20 dB to 0dB ramp within 15ms after end of transmit signal. |
| Power: |
115/230 VAC +/- 10%, 47 to 63 Hz, 220 W
maximum. |
| Auxiliary Power: |
IEC connector, unfused, 6A
maximum. |
| Environmental: |
Operational: -5 to 50°C, Storage: –15 to 85°C |
| Dimensions: |
45.7cm (L) x 43cm (W) x 13cm (H), 18kg |
Receiver Model 5210A
| Amplifier: |
Differential common mode rejection: 100dB at 60Hz. Sensitivity 30µV RMS in, produces 1V RMS out at 90dB total
gain with TVG. |
| Signal to Noise: |
20dB at 100dB gain 1kHz centre frequency and 1kHz bandwidth. |
| Coarse Gain: |
40dB maximum. |
| Fine Gain: |
0-30dB in 3dB increments. |
| Filter: |
Low pass and high pass, active type,
maximally flat, 24dB/octave minimum roll-off, 0 gain, 0.02kHz to 15kHz
adjustable in ½ octave increments. Knobs interlock to prevent overlap. |
| TVG: |
Dynamic range: 30dB.
Rate: approximately flat to 30dB in 14 ms.
Manual delay: vernier adjust from 1 to 14ms with multiplier of x 1, x 10, x 100
and internal select of x 1000. |
| AGC: |
Attack adjustable from 330µs to 330ms.
Decay: adjustable from 330µs to 330ms.
Range: 20dB. |
| Power: |
115/230VAC ±10% (internal switch selectable),
47 to 63Hz, 45W maximum. |
| Environmental: |
Operational: -5 to 50°C, Storage: –15 to 85°C |
| Dimensions: |
45.7cm (L) x 43cm (W) x 17.8cm (H), 12kg. |
Models 132B & 136A (fitted with
Model T135 transducers for general sub-bottom profiling)
|
Beam width: |
55° at 3.5kHz. 40° at 5.0kHz. 30°
at 7.0kHz (4 Transducers) |
|
Source level:
|
214dB re 1 µPa/1m.
|
|
Dimensions: |
132B: |
70cm (L) x 52cm (W) x 46cm (H), 120kg. |
| |
Mounting Staff: |
One section 183cm, two sections 360cm. |
| |
136A: |
156cm (L) x 46cm (W) x 46cm (H), 125kg. |
Model 134 (fitted with Model T135
transducers for general sub-bottom profiling)
|
Frequency: |
3 to 7 kHz (for maximum efficiency) |
| Power:
|
10
kW at 0.75% duty cycle, typical. |
|
Source level (for 10kW input): |
16 transducer
array 225dB re 1µPa/1m
8 or 9 transducers 220dB re 1µPa/1m
4 transducers
214dB re 1µPa/1m |
|
Dimensions of 16 transducer array: |
82cm (L)
x 82cm (W) x 34cm (H) |
Approximately transmitting beams.
| Size |
Frequency |
Combined |
Separate
Fwd/Aft |
Separate
Port/Stbd |
| 16 |
3.5
5.0
7.0 |
30
20
15 |
30
20
15 |
55
45
40 |
| 9 |
3.5
5.0
7.0 |
40
30
20 |
40
30
20 |
55
45
40 |
| 8 |
3.5
5.0
7.0 |
30x55
20x45
15x40 |
30
20
15 |
80
60
50 |
| 4 |
3.5
5.0
7.0 |
55
45
35 |
120
100
80 |
55
55
35 |
Specifications subject to change without
notice.
|