Transmitter - Model 5430A

Output: 10 kW with 0.75% duty cycle, continuously adjustable. 2 to 12 kHz, continuously adjustable. Short circuit proof. Impedance matched.
Pulse Cycles: 1, 2, 4, 8, 16, or 32 cycles of the frequency selected.  The transmitted output pulse will be phase coherent within 22.5°.
Key: External: 2 to 12 V pulse, either + or – leading edge triggered. Maximum width 50ms to eliminate double triggering. Transformer isolated.
  Internal: Set by internal potentiometer, 1 to 10pps, uncalibrated.
Output to Receiver or digital sonar processing system: Transformer isolated. Frequency response flat between approximately 1 kHz and 20 kHz. Two modes of operation:
A: Flat gain –0 dB gain
B: Short range TVG -20 dB (10:1) of attenuation during transmit pulse and a –20 dB to 0dB ramp within 15ms after end of transmit signal.
Power: 115/230 VAC +/- 10%, 47 to 63 Hz, 220 W maximum.
Auxiliary Power: IEC connector, unfused, 6A maximum.
Environmental: Operational: -5 to 50°C, Storage: –15 to 85°C
Dimensions: 45.7cm (L) x 43cm (W) x 13cm (H), 18kg

Receiver Model 5210A

Amplifier: Differential common mode rejection: 100dB at 60Hz. Sensitivity 30µV RMS in, produces 1V RMS out at 90dB total gain with TVG.
Signal to Noise: 20dB at 100dB gain 1kHz centre frequency and 1kHz bandwidth.
Coarse Gain: 40dB maximum.
Fine Gain: 0-30dB in 3dB increments.
Filter: Low pass and high pass, active type, maximally flat, 24dB/octave minimum roll-off, 0 gain, 0.02kHz to 15kHz adjustable in ½ octave increments. Knobs interlock to prevent overlap.
TVG: Dynamic range: 30dB.
Rate: approximately flat to 30dB in 14 ms.
Manual delay: vernier adjust from 1 to 14ms with multiplier of x 1, x 10, x 100 and internal select of x 1000.
AGC: Attack adjustable from 330µs to 330ms.
Decay: adjustable from 330µs to 330ms.
Range: 20dB.
Power: 115/230VAC ±10% (internal switch selectable), 47 to 63Hz, 45W maximum.
Environmental: Operational: -5 to 50°C, Storage: –15 to 85°C
Dimensions: 45.7cm (L) x 43cm (W) x 17.8cm (H), 12kg.

Models 132B & 136A (fitted with Model T135 transducers for general sub-bottom profiling)

Beam width: 55° at 3.5kHz. 40° at 5.0kHz. 30° at 7.0kHz (4 Transducers)
Source level: 214dB re 1 µPa/1m.
Dimensions: 132B: 70cm (L) x 52cm (W) x 46cm (H), 120kg.
  Mounting Staff: One section 183cm, two sections 360cm.
  136A: 156cm (L) x 46cm (W) x 46cm (H), 125kg.

Model 134 (fitted with Model T135 transducers for general sub-bottom profiling)

Frequency: 3 to 7 kHz (for maximum efficiency)
Power: 10 kW at 0.75% duty cycle, typical.
Source level (for 10kW input): 16 transducer array 225dB re 1µPa/1m
8 or 9 transducers 220dB re 1µPa/1m
4 transducers 214dB re 1µPa/1m
Dimensions of 16 transducer array: 82cm (L) x 82cm (W) x 34cm (H)

Approximately transmitting beams.

Size Frequency Combined Separate
Fwd/Aft
Separate
Port/Stbd
16 3.5
5.0
7.0
30
20
15
30
20
15
55
45
40
9 3.5
5.0
7.0
40
30
20
40
30
20
55
45
40
8 3.5
5.0
7.0
30x55
20x45
15x40
30
20
15
80
60
50
4 3.5
5.0
7.0
55
45
35
120
100
80
55
55
35

Specifications subject to change without notice.